Examples Of Maxdax Configuration (T1) - Lucent Technologies MAX 6000 Network Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Configuring WAN Access
Configuring MAXDAX
E=Termsrv
D=Diagnostics
V=View ChanGroup/s
To display the current MAXDAX channel-group mappings, press V or select V=View
ChanGroup/s. The current MAXDAX configuration appears, including a
channel-by-channel listing of channel groupings.
For example:
S:P:Ch
>1:1:01
1:1:02
1:1:03
1:1:04
1:1:05
1:1:06
1:1:07
1:1:08
1:1:09
1:1:10
1:1:11
1:1:12
In the channel-group display:
In the example, if the unit receives a call on channel 12 of the first line in the first slot, it places
the outgoing call on channel 11 of the first line in the first slot.
Note: The unit cannot make an outgoing call on the same channel on which it is receiving a
call. Make sure you do not configure a channel with identical channel-group and destination
channel-group numbers.

Examples of MAXDAX configuration (T1)

This section describes two MAXDAX environments, including specific parameter settings.
3-82
Dest | ChanGroup
777 |
777 |
777 |
777 |
777 |
777 |
777 |
777 |
777 |
777 |
777 |
333 |
S indicates the slot number. For a MAX 6000 unit, the slot number can be either 1 or 2.
For a MAX 3000 unit, the slot number is always 1.
P indicates the T1/E1 lines in the slot. The unit supports two T1/E1 lines per slot.
Ch indicates the channel number on the T1 line.
Dest indicates the value specified for Net/T1 (E1) > Line Config > Line Config profile >
Line N > Net2Net Incoming Calls > Ch N Dest ChanGroup.
ChanGroup indicates the value specified for Net/T1 (E1) > Line Config > Line Config >
Line N > Net2Net ChanGroup ID > Ch N ChanGroup for the specified channel.
ChanGroup is the group to which you have assigned the channel. When the unit receives a
call on a channel, it makes the outgoing call on the first available channel for which
Net/T1 (E1) > Line Config > Line Config profile > Line N > Net2Net ChanGroup ID > Ch
N ChanGroup matches Net/T1 (E1) > Line Config > Line Config profile > Line N >
Net2Net Incoming Calls > Dest ChanGroup for the channel on which the unit receives the
incoming call.
0
0
0
0
0
0
0
0
0
0
333
777
MAX 6000/3000 Network Configuration Guide