Configuring Frame Relay
Concentrating incoming calls onto Frame Relay
Parameter
Encaps
FR Direct
FR Prof
FR Dlci
Route IP
LAN Adrs

Settings in a RADIUS profile

Following are the relevant RADIUS attributes for FR Direct connections:
Attribute
Framed-Protocol (7)
Ascend-FR-Direct (219) Enables/disables FR-Direct mode for this connection. FR-Direct-
Ascend-FR-Direct-
Profile (220)
Ascend-FR-Direct-
DLCI (221)
Ascend-Route-IP (228)
5-22
Preliminary January 4, 2001
LAN Adrs=10.111.112.113/24
Session options
FR Direct=Yes
FR Prof=
FR Dlci=16
Specifies
Specifies the supported encapsulation protocol. Must be set to
PPP, MP, or MPP for Frame Relay Direct connections.
Enables/disables FR-Direct mode for this connection.
Specifies the name of the Frame Relay profile that defines the
datalink.
DLCI assigned in a Connection profile to a next hop on the
specified interface. Multiple FR-Direct Connection profiles can
refer to the same DLCI in this setting.
Enables/disables IP routing for this connection. Must be enabled
for the MAX to send data back to the appropriate PPP caller.
Specifies the PPP caller's IP address. As the MAX receives return
packets for many Frame Relay Direct connections on the same
DLCI, it uses this address to determine which PPP caller should
receive the return packets.
Value
The encapsulation protocol. Must be set to PPP (1), MP (262), or
MPP (256) for FR-Direct connections.
No (0) is the default. Set to FR-Direct-Yes (1) for FR-Direct
connections.
Name of the Frame-Relay profile that defines the datalink.
DLCI assigned in a Connection profile to a next hop on the
specified interface. Multiple FR-Direct Connection profiles can
refer to the same DLCI in this setting.
Enables/disables IP routing for this connection. (IP is enabled by
default. If this attribute is present, it must be set to Route-IP-Yes
to enable the MAX to send data back to the appropriate PPP
caller.