BRI channels in the same trunk group. For details, see "Configuring outbound calls" on
page 3-69.

Configuring add-on numbers and SPIDs

The Pri Num and Sec Num parameters define additional telephone numbers for multichannel
calls, and SPIDs identify services provisioned for your ISDN line. For more details about
add-on numbers and SPIDs, see "Assigning telephone numbers" on page 3-5.
To configure add-on numbers and SPIDs for your ISDN BRI line, open a Net/BRI > Line
Config > Line Config profile, then open the line's Line N subprofile and set the following
parameters:
Parameter
Pri Num
Pri SPID
Sec Num
Sec SPID
For detailed information about each parameter, see the MAX Reference. For more information
about SPIDs, see "SPIDS (for Net/BRI lines)" on page 3-6.
Note: After you have configured the line, you might need to configure the card for outbound
calls (as described in "Configuring the Net/BRI line for outbound calls" on page 3-38).
Typical Net/BRI configurations, with examples
Typical Net/BRI line configurations for MAX units include configurations for incoming
switched connections and for outbound calls.
Configuring incoming switched connections
The following procedure assumes that the MAX BRI lines connect to a NI-1 switch running in
multipoint mode:
1
2
3
4
5
6
7
8
MAX 6000/3000 Network Configuration Guide
Specifies
Primary add-on number for the ISDN BRI line. If you configure the line
for point-to-point service, this is the only number associated with the line.
Primary Service Profile Identifier (SPID) for ISDN BRI line.
Secondary add-on number for the ISDN BRI line. If you configure the
line for point-to-point service, Sec Num is not applicable.
SPID (Service Profile Identifier) associated with the secondary telephone
number for the ISDN BRI line.
Open a Net/BRI > Line Config profile.
Set the Name parameter to assign a name to the profile.
Set the Switch Type parameter to specify the carrier switch type.
Set the BRI Analog Encode parameter to specify analog encoding for modem calls.
Open the Line 1 subprofile, and set Enable to Yes to enable the line.
Set the Link Type parameter to specify multipoint mode.
Configure the B channels for switched usage and for routing to the local network.
Specify the primary and secondary add-on numbers and their associated SPIDs.
Configuring WAN Access
Configuring ISDN BRI network cards
3-37

Advertisement

Table of Contents
loading

This manual is also suitable for: