Port-to-port routing
This routing allows the routing of calls from one POTS port on a MAX to another POTS port
on the same MAX. The ports do not need to be on the same MAXPOTS slot card, and no other
trunks are necessary. You can configure calls 4001 and 4002 to be routed to POTS ports 1 and
2, respectively, on MAXPOTS slot 3 card. For example:
System
Sys Config
System
Call Routes
System
Call Routes
You can define the call route to allow calls from POTS port 8, dialing telephone number 4001
to connect to POTS port 4. For example:
System
Call Routes
MAX 6000/3000 Network Configuration Guide
Configuring POTS capability on the MAX 6000 and MAX 3000
CRprofile1
Name=CRprofile1
Active=Yes
Phone Number=4001
Src Slot=0
Src Port=0
Call Rte Type=Trunk-Any
Dst Chan Grp=0
Dst Trnk Grp=0
Dst Slot=3
Dst Port=1
CRprofile2
Name=CRprofile2
Active=Yes
Phone Number=4002
Src Slot=0
Src Port=0
Call Rte Type=Trunk-Any
Dst Chan Grp=0
Dst Trnk Grp=0
Dst Slot=3
Dst Port=2
CRprofile3
Name=CRprofile3
Active=Yes
Phone Number=4001
Src Slot=3
Src Port=8
Call Rte Type=Trunk-Any
Dst Chan Grp=0
Dst Trnk Grp=0