Table 6-2. X.3 parameters (continued)
Parameter
20
21
22
Table 6-3 lists the permanent (noncustom) X.3 profiles and the settings of their parameters.
Table 6-3. X.3 profiles
X.3 profile
CRT
INFONET
SCEN
CC_SSP
CC_TSP
HARDCOPY
HDX
SHARK
MAX 6000/3000 Network Configuration Guide
Description
Possible values
Echo mask
0—None (full packet)
1—Alphanumeric
2—Carriage return (the default)
4—ESC, BEL, ENQ, ACK
8—DEL, CAN, DC2
16—ETX, EOT
32—HT, LT, VT, FF
64—All other characters in columns 0 and 1
of International Alphabet #5
Parity treatment
0—No parity checking or generation
1—Parity checking
2—Parity generation
Page wait
0—No page wait
1–255—The number of linefeed characters
sent by the PAD before page wait condition
Contents
1:64, 2:1, 3:2, 4:0, 5:0, 6:5, 7:2, 8:0, 9:0, 10:0, 11:0, 12:1,
13:4, 14:0, 15:1, 16:8, 17:24, 18:18, 19:2, 20:0, 21:3, 22:0
1:1, 2:0, 3:2, 4:0, 5:0, 6:0, 7:21, 8:0, 9:2, 10:0, 12:1, 13:0,
14:2, 15:1, 16:8, 17:24, 18:18, 19:0, 20:0, 21:0, 22:0
1:64, 2:1, 3:2, 4:0, 5:1, 6:5, 7:21, 8:0, 9:0, 10:0, 12:1, 13:4, 14:0,
15:1, 16:127, 17:24, 18:18, 19:1, 20:0, 21:0, 22:0
1:1, 2:1, 3:126, 4:0, 5:1, 6:1, 7:2, 8:0, 9:0, 10:0, 12:1, 13:0, 14:0,
15:0, 16:127, 17:24, 18:18, 19:1, 20:0, 21:0, 22:0
1:0, 2:0, 3:0, 4:20, 5:0, 6:0, 7:2, 8:0, 9:0, 10:0, 12:0, 13:0, 14:0, 15:0,
16:127, 17:24, 18:18, 19:1, 20:0, 21:0, 22:0
1:64, 2:1, 3:2, 4:0, 5:2, 6:5, 7:21, 8:0, 9:5, 10:80, 12:1, 13:4, 14:5,
15:1, 16:8, 17:24, 18:18, 19:1, 20:0, 21:3, 22:0
1:1, 2:1, 3:2, 4:0, 5:2, 6:5, 7:2, 8:0, 9:0, 10:0, 12:1, 13:4, 14:0, 15:1,
16:8, 17:24, 18:18, 19:2, 20:0, 21:3, 22:0
1:0, 2:0, 3:2, 4:0, 5:0, 6:0, 7:2, 8:0, 9:0, 10:0, 12:0, 13:0, 14:0, 15:0,
16:0, 17:0, 18:0, 19:0, 20:0, 21:0, 22:0
Configuring X.25
Setting up X.25 PAD sessions