Figure 9-6. Creating a subnet for the MAX
10.0.0.0
You can place the MAX unit on a subnet of that network by including a subnet mask in the IP
address specification. For example:
1
2
3
4
With this subnet address, the MAX unit requires a static route to the backbone router on the
main network. Otherwise, it can only communicate with devices on the subnets to which it is
directly connected. To create the static route and make the backbone router the default route:
1
2
3
For more information about IP Route profiles, see "Configuring IP routes" on page 9-55.
To verify that the unit is connected to the local network, invoke the terminal-server interface
and Ping a local IP address or hostname. For example:
ascend% ping 10.1.2.3
MAX 6000/3000 Network Configuration Guide
GRF
10.0.0.17
MAX
10.2.3.1/24
Open Ethernet > Mod Config > Ether Options.
Set the IP Adrs parameter to specify the IP subnet address for the MAX on the Ethernet
network. For example:
Ethernet
Mod Config
Ether options...
IP Adrs=10.2.3.1/24
Set the RIP parameter to specify that the MAX receives RIP updates from the local GRF
router:
RIP-Recv=v2
Exit the profile and, at the exit prompt, select the exit and accept option.
Open the Default IP Route profile in the Static Rtes menu.
Set the Gateway parameter to specify the IP address of a backbone router. For example:
Ethernet
Static Rtes
Default
Name=Default
Active=Yes
Dest=0.0.0.0/0
Gateway=10.0.0.17
Preference=100
Metric=1
DownPreference=140
DownMetric=7
Private=Yes
Exit the profile and, at the exit prompt, select the exit and accept option.