Configuring IP Routing
Configuring WAN interfaces
To configure the Site B Pipeline:
1
2
3
4
Following are comparable RADIUS profiles:
pipeline1 Password = "localpw"
route-max-1 Password = "ascend", Service-Type = Outbound-User
pipeline1-out Password = "localpw", Service-Type = Outbound-User

Configuring a router-to-router connection on a subnet

In the sample network illustrated in Figure 9-13, the MAX unit connects telecommuters with
their own Ethernet networks to the corporate backbone. The unit is on a subnet, and assigns
subnet addresses to the telecommuters' networks.
9-42
Open the Connection profile for the Site A MAX.
Set the Station parameter to specify the Site A MAX unit's name, set the Active profile to
activate the profile, and specify the desired encapsulation options. For example:
Ethernet
Connections
Connection profile 1
Station=MAXA
Active=Yes
Encaps=MPP
Encaps options...
Send Auth=CHAP
Recv PW=localpw
Send PW=remotepw
Set the Route IP parameter to enable IP routing and set the LAN Adrs parameter to specify
the IP address of the MAX at Site A.
Route IP=Yes
IP options...
LAN Adrs=10.2.3.1/22
Exit the profile and, at the exit prompt, select the exit and accept option.
Service-Type = Framed-User,
Framed-Protocol = PPP,
Framed-IP-Address = 10.9.8.10/22,
Framed-IP-Netmask = 255.255.252.0
Framed-Route = "10.9.8.10/22 10.9.8.10 1 n pipeline1-out"
User-Name = "pipeline1",
Ascend-Dial-Number = "9-1-333-555-1212",
Framed-Protocol = PPP,
Framed-IP-Address = 10.9.8.10,
Framed-IP-Netmask = 255.255.252.0,
Ascend-Send-Auth = Send-Auth-PAP,
Ascend-Send-Password = "remotepw"