Example Of A Mp Connection With Bacp - Lucent Technologies MAX 6000 Network Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Following is a comparable RADIUS profile:
fred Password = "localpw"

Example of a MP connection with BACP

To configure a MP connection that uses BACP:
1
2
3
4
5
6
7
MAX 6000/3000 Network Configuration Guide
Service-Type = Framed-User,
Framed-Protocol = MP,
Framed-IP-Address = 10.10.1.2,
Framed-IP-Netmask = 255.255.255.255,
Ascend-Base-Channel-Count = 2,
Ascend-Maximum-Channels = 2
Open the Answer profile.
Enable PPP and MP encapsulation and specify the appropriate routing, bridging, and
authentication values. For example:
Ethernet
Answer
Encaps
MP=Yes
PPP=Yes
PPP Options
Route IP=Yes
Route IPX=Yes
Bridge=Yes
Recv Auth=Either
Enable BACP to monitor bandwidth requirements on the basis of received packets:
BACP=Yes
Exit the profile and, at the exit prompt, select the exit and accept option.
Open a Connection profile, specify the name of the remote device, and activate the profile.
For example:
Ethernet
Connections
chloe
Station=chloe
Active=Yes
Select MP encapsulation and set the MP authentication options. For example:
Encaps=MP
Encaps Options
Send Auth=PAP
Send PW=remotepw
Aux Send PW=N/A
Recv PW=localpw
Enable BACP to monitor bandwidth requirements for packets transmitted on this
connection, and configure the Lucent criteria for bandwidth management. For example:
BACP=Yes
Base Ch Count=1
Min Ch Count=1
Max Ch Count=2
Inc Ch Count=1
Configuring Individual WAN Connections
Configuring MP, MP+ and BACP connections
4-51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max 3000

Table of Contents