Lucent Technologies MAX 6000 Network Configuration Manual page 451

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

2
3
4
5
6
7
MAX 6000/3000 Network Configuration Guide
IPX Frame=802.2
IPX Enet #=00000000
For details, see Chapter 12, "Configuring IPX Routing."
Open the ATMP Options subprofile, set ATMP Mode to Home, and set Type to Gateway.
Specify the password used to authenticate the tunnel. It must match the
Ascend-Home-Agent-Password attribute of each mobile client's RADIUS profile.
Set SAP Reply to Yes. The profile now has the following settings:
ATMP options...
ATMP Mode=Home
Type=Gateway
Password=private
SAP Reply=Yes
UDP Port=5150
GRE MTU=1472
Force fragmentation=No
Idle limit=0
ATMP SNMP Traps=No
Exit the profile and, at the exit prompt, select the exit and accept option.
Open a Connection profile and configure an IP routing connection to the Foreign Agent.
For example:
Ethernet
Connections
any Connection profile
Station=foreign-agent
Active=Yes
Encaps=MPP
Dial #=555-1213
Route IP=Yes
Encaps options...
Send Auth=CHAP
Recv PW=foreign-pw
Send PW=home-pw
IP options...
LAN Adrs=10.65.212.226/24
Open a Connection profile and configure a nailed WAN link that routes IPX to the home
network. For example:
Ethernet
Connections
any Connection profile
Station=homenet
Active=Yes
Encaps=MPP
PRI # Type=National
Dial #=555-1212
Route IPX=Yes
Encaps options...
Send Auth=CHAP
Recv PW=homenet-pw
Send PW=my-pw
Setting Up Virtual Private Networks
Configuring ATMP tunnels
(for ISDN PRI lines only)
11-21