Using Maxdax - Lucent Technologies MAX 6000 Network Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Configuring WAN Access
Configuring E1 lines

Using MAXDAX

MAXDAX enables you to route incoming calls from PRI lines to specific outgoing channels
on the same or different PRI lines. To implement MAXDAX, you must set parameters in the
Net2Net Incoming Calls and Net2Net ChanGroup ID profiles. In the Net2Net Incoming Calls
profile, you define parameters used in configuring channels on which the MAX unit receives
incoming calls. In the Net2Net ChanGroup ID profile, you define parameters used in
configuring channels for outbound calls.
For complete information about MAXDAX, see "Configuring MAXDAX" on page 3-74. Or,
for detailed information about each parameter, see the MAX Reference.
Following are the parameters you set in the Net/E1 > Line Config profile > Line N > Net2Net
Incoming Calls profile:
Parameter
Ch N
Ch N Dest ChanGroup
Ch N Dial Plan #
Ch N #DialPlanSelDigits The number of leading digits the unit strips from the called
In the Net/E1 > Line Config > Line Config profile > Line N > Net2Net ChanGroup ID profile,
you set the following parameters:
Parameter
Ch N
Ch N ChanGroup
Configuring channels
Each built-in E1 connection supports 32 channels, each of which can support one
single-channel connection. Depending on the signaling mode used on the line, all 32 channels
are available for user data, or 31 channels are available for data and the 32nd channel is
reserved for signaling. Each channel can be either switched or nailed. You can assign a
switched channel to a slot/port combination. To make a nailed channel available to a
Connection or call profile, you assign the channel to a group. You can also assign channels to
hunt groups. (For the definition of call profile, see "Assigning nailed channels to groups" on
page 3-12.)
Each E1 line supports 32 channels, of which one is used for framing. Also, you can use one of
the channels for a PRI signalling. The Ch N parameters are repeated for each channel in the
line
3-24
Specifies
A switched connection for MAXDAX. That is, you must set Ch N
to Switched.
The channel group number to which the MAX unit directs
outbound calls.
A Dial Plan profile for the calls received by this channel.
number.
Specifies
A switched connection for MAXDAX. That is, you must set Ch N
to Switched.
The group to which the channel is assigned.
MAX 6000/3000 Network Configuration Guide