Configuring Frame Relay
Configuring the MAX as a Frame Relay switch
The next set of parameters on MAX-39 specifies the circuit between its two Frame Relay
interfaces:
Ethernet
Connections
Ethernet
Connections

Using RADIUS profiles

The following profiles define the datalinks from MAX-42 to the MAX and MAX-39:
frdlink-max-25 Password="ascend", User-Service=Dialout-Framed-User
frdlink-max-26 Password="ascend", User-Service=Dialout-Framed-User
The next set of profiles specifies the circuit on MAX-42:
permconn-max-14 Password="ascend", User-Service=Dialout-Framed-User
5-32
Preliminary January 4, 2001
max42
Name=max42
Active=Yes
Encaps=FR-Cir
Route IP=No
Encaps options
FR Prof=nni-42
DLCI=200
FR Circuit=cir-39
max39
Name=max39
Active=Yes
Encaps=FR-Cir
Route IP=No
Encaps options
FR Prof=dce-p130
DLCI=300
FR Circuit=cir-39
Ascend-FR-Profile-Name="dce-max",
Ascend-Call-Type=Nailed,
Ascend-FR-Type=Ascend-FR-DCE,
Ascend-FR-Nailed-Grp=555
Ascend-FR-Profile-Name="nni-39",
Ascend-Call-Type=Nailed,
Ascend-FR-Type=Ascend-FR-NNI,
Ascend-FR-Nailed-Grp=999
User-Name="max"
Framed-Protocol=FR-CIR,
Ascend-Route-IP=Route-IP-No,
Ascend-FR-DLCI=100,
Ascend-FR-Profile-Name="dce-max",
Ascend-FR-Circuit-Name="cir-42"