Table 6-1. Sample telco subscription form (continued)
Subscription-item
Maximum number of outstanding data
packets allowed between a DTE and a DCE
before acknowledgment is required (W)
Number of PVCs
Highest PVC channel number
Default packet size
Minimum packet size
Maximum packet size
To configure the X.25 profile to comply with the subscription form in this example:
1
2
3
4
5
6
7
8
MAX 6000/3000 Network Configuration Guide
Open the X.25 profile, assign the profile a name, and activate it:
Ethernet
X.25...
X.25 profile
Name=ATT
Active=Yes
Set Call Type to Nailed and specify the nailed group number:
Call Type=Nailed
Nailed Grp=7
Set the LAPB parameters to comply with the settings in the subscription form:
LAPB T1=3
LAPB N2=10
LAPB k=7
Set the X.25 Node Type to DTE, as specified in the subscription form:
X.25 Node Type=DTE
Configure the profile to support up to eight Switched Virtual Circuits:
X.25 Link Setup Mode=ACTIVE
X.25 lowest PVC=0
X.25 highest PVC=0
X.25 lowest SVC=1
X.25 highest SVC=8
Configure packet sizes and flow control:
X.25 window size=2
X.25 pkt size=128
X.25 Min pkt size=64
X.25 Max pkt size=1024
Specify the X.121 source address to use on this link:
X.121 src addr=031344159782738
Exit the profile and, at the exit prompt, select the exit and accept option.
Configuring the logical link to an X.25 network
Value
X.25 profile setting
2
X.25 Window Size=2
0
X.25 Lowest PVC=0
0
X.25 Highest PVC=0
128
X.25 Pkt Size=128
64
X.25 Min Pkt Size=64
1024
X.25 Max Pkt Size=1024