Routing Parameters In Radius - Lucent Technologies MAX 6000 Network Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Configuring Frame Relay
Concentrating incoming calls onto Frame Relay

Routing parameters in RADIUS

In addition to the attributes described in "Overview of DLCI interface settings" on page 5-13,
the following attribute-value pairs must be specified in the permconn profile of a Frame Relay
gateway:
Attribute
Ascend-Route-IP (228)
Framed-Address (8)
Framed-Netmask (9)
Examples of a gateway configuration
In the following example, the MAX acts as a gateway between a client that dials in with the
address 10.1.2.3/29, and a remote router that is reachable across Frame Relay, as shown in
Figure 5-8:
Figure 5-8. Frame Relay gateway
The following set of parameters configures an MP+ Connection profile for the dial-in client in
Figure 5-8:
Ethernet
Connections
Following is a comparable RADIUS profile:
mpp-client Password="clientpw", User-Service=Dialout-Framed-User
5-20
Preliminary January 4, 2001
Value
Enables/disables IP routing for this connection. (IP is enabled by
default. If this attribute is present, it must be set to Route-IP-Yes
for Frame Relay gateway connections.)
Destination IP address, which lies at the end of a PVC whose first
hop is known by the specified DLCI.
A subnet mask for Framed-Address.
Frame Relay
10.9.8.7/24
mpp-client
Name=mpp-client
Active=Yes
Encaps=MPP
Encaps options
Recv PW=clientpw
IP options
LAN Adrs=10.1.2.3/29
Framed-Protocol=MPP,
Framed-Address=10.10.1.3,
Framed-Netmask=255.255.255.248
DLCI 55