If an IPX filter is applied as a call filter and a comparison succeeds, the forwarding action is
either to reset the idle timer or not, depending on how the filter is defined. If an IPX filter is
applied as a data filter, the forwarding action is either to forward the packet or drop it.

Specifying a filter's direction

A local Filter profile can define up to 12 input-filter specifications and 12 output-filter
specifications. Following are the relevant parameters, shown with their default settings:
Ethernet
Filters
Parameter
Name
Input Filters (1–12)
Output Filters (1–12)
Valid
In a RADIUS profile, each filter is specified separately by using the Ascend-Data Filter and
Ascend-Call Filter attributes. As is always the case with filters, the order in which they are
applied within the user profile is significant.
In a RADIUS filter definition, you specify the direction in which to monitor the data stream as
in or out. This specification provides the same function as the Input Filters and Output
Filters parameters in a local profile. The following example shows an input-filter definition in
RADIUS.
MAX 6000/3000 Network Configuration Guide
If the Dst Socket Cmp parameter is not set to None, compare the Dst Socket # to the
destination socket number of the packet. If they do not match as specified by the Dst
Socket Cmp parameter, the comparison fails.
Filter profile
Name
Input Filters...
In Filter (1-12)
Valid=No
Output Filters...
Out Filter (1-12)
Valid=No
Specifies
Name of a Filter profile. For details, see "Example of applying a
filter to a LAN interface" on page 15-29.
Each filter can contain up to 12 input-filter specifications, which
are defined individually and applied in order (1–12) to the inbound
packet stream. The order in which the input filters are defined is
significant.
Each filter can contain up to 12 output-filter specifications, which
are defined individually and applied in order (1–12) to the
outbound packet stream. The order in which the output filters are
defined is significant.
Enable/disable the filter specification. With a setting of No (the
default), the specification is skipped when filtering the data
stream. Set this parameter Yes for each defined filter you intend to
use.