Parameter
X.25 pkt size
X.25 Min pkt size
X.25 Max pkt size
X.25 lowest PVC
X.25 highest PVC
X.25 lowest SVC
X.25 highest SVC
X.25 Clear/Diag
X.25 Reset/Diag
X.25 Restart/Diag
X.25 Options
X.25 Rev Charge
Accept
X.25 Network Type
X.25 T20
X.25 R20
X.25 T21
X.25 T22
X.25 R22
X.25 T23
X.25 R23
MAX 6000/3000 Network Configuration Guide
Configuring the logical link to an X.25 network
Specifies
The default (128) maximum, and minimum number of bytes in the
data field of a data packet.
Minimum number of bytes in the data field of a data packet when
negotiating the packet size with a remote X.25 switch.
Maximum number of bytes in the data field of a data packet when
negotiating the packet size with a remote X.25 switch. Note that a
large packet size improves throughput by reducing the overhead
associated with header transmission. However, a large packet size also
increases the probability of transmission errors, causes increased
transmission delays on the network, and is associated with processing
delays at the host.
The X.25 Lowest PVC and X.25 Highest PVC parameters define a
range of PVCs from 1 to 4096. If the lowest PVC number is zero, no
PVCs are supported.
The X.25 Lowest SVC and X.25 Highest SVC parameters define a
range of SVCs from 1 to 4096. If the lowest SVC number is zero, no
SVCs are supported.
Whether or not Clear-Request packets include the diagnostic field. The
default is No.
Whether or not Reset-Request packets include the diagnostic field.
The default is No.
Whether or not Restart-Request packets include the diagnostic field.
The default is No.
None (no options) or NPWS (specifying that the MAX negotiates
packet and window size). The default is None.
Whether or not the MAX accepts packets that request charge reversal.
The default is No.
Type of network used by the link. At present, the MAX supports only
the CCITT network type.
The duration of the Restart timer (the number of one-second ticks the
MAX waits before retransmitting a Restart-Request packet).
The number of Restart-Request retransmits the MAX sends before
waiting indefinitely for a response.
The duration of the Call-Request timer (the number of one-second
ticks the MAX waits before clearing an unacceptable outgoing call).
Sets the duration of the Reset-Request timer (the number of
one-second ticks the MAX waits before retransmitting a
Reset-Request packet).
The number of times the MAX retransmits a Reset-Request packet
before clearing a call.
The duration of the Clear-Request timer (the number of one-second
ticks the MAX waits before retransmitting a Clear-Request packet).
The number of Clear-Request retransmits the MAX sends before
waiting indefinitely for a response.