Example Of A Ppp Connection - Lucent Technologies MAX 6000 Network Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Example of a PPP connection

Figure 4-1 shows the MAX unit with a PPP connection to a remote user who is running
Windows 95 with a TCP/IP stack and PPP dialup software. The dial-in user has a modem, so
the call is asynchronous and uses only one channel.
Figure 4-1. A PPP connection
To configure this PPP connection:
1
2
3
4
5
6
Following is a comparable RADIUS profile:
tommy Password = "localpw"
MAX 6000/3000 Network Configuration Guide
MAX
Make sure the Answer profile enables PPP encapsulation and has the appropriate routing,
bridging, and authentication settings. For example:
Ethernet
Answer
Encaps
PPP=Yes
PPP Options
Route IP=Yes
Route IPX=Yes
Bridge=Yes
Recv Auth=Either
Exit the profile and, at the exit prompt, select the exit and accept option.
Open an Ethernet > Connections > Connection profile.
Specify the name of the remote device and activate the profile. For example:
Ethernet
Connections
tommy
Station=tommy
Active=Yes
Note: Make sure that you specify the Station name exactly, including case.
Select PPP encapsulation and set the appropriate PPP Options. For example:
Encaps=PPP
Encaps Options
Send Auth=CHAP
Send PW=remotepw/A
Recv PW=localpw
The Send Auth parameter should be set to CHAP or PAP. Both sides of the connection
must support the selected authentication protocol and the selected compression methods.
Exit the profile and, at the exit prompt, select the exit and accept option.
Service-Type = Framed-User,
Configuring Individual WAN Connections
Configuring PPP connections
WAN
Modem
Windows95
with TCP/IP
and PPP
4-45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max 3000

Table of Contents