Lucent Technologies MAX 6000 Network Configuration Manual page 454

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Setting Up Virtual Private Networks
Configuring ATMP tunnels
2
3
4
5
6
Finally, set the Home Agent aspect of the multimode configuration:
1
11-24
Auth Pool=No
Auth Req=Yes
Password Server=No
Password Port=N/A
Local Profile First=No
Sess Timer=0
Auth Src Port=0
Auth Send Attr 6,7=Yes
For detailed information about each parameter, see the MAX Reference.
Exit the profile and, at the exit prompt, select the exit and accept option.
On the RADIUS server, open the RADIUS user profile and create an entry for a mobile
client. For example:
node1 Password="top-secret"
Ascend-Metric=2,
Framed-Protocol=PPP,
Ascend-IP-Route=Route-IP-Yes,
Framed-Address=200.1.1.2,
Framed-Netmask=255.255.255.0,
Ascend-Primary-Home-Agent=10.1.2.3,
Ascend-Home-Agent-Password="private"
Ascend-Home-Agent-UDP-Port=5150
Ascend-Home-Network-Name=home-agent
Close the user profile.
Open a Connection profile and configure an IP routing connection to the Network A
Home Agent. For example:
Ethernet
Connections
any Connection profile
Station=home-agent
Active=Yes
Encaps=MPP
Dial #=555-1212
Route IP=Yes
Encaps options...
Send Auth=CHAP
Recv PW=home-pw
Send PW=foreign-pw
IP options...
LAN Adrs=10.1.2.3/24
Exit the profile and, at the exit prompt, select the exit and accept option.
Open a Connection profile and configure an IP routing connection to the Network B
Foreign Agent. For example:
Ethernet
Connections
any Connection profile
Station=foreign-agent
Active=Yes
Encaps=MPP
MAX 6000/3000 Network Configuration Guide