Configuring carrier-specific services

To enable the MAX to communicate with your carrier's switch, and vice versa, obtain values
for the Call-by-Call, T1-PRI:PRI # Type, and T1-PRI:NumPlanID parameters from your
service provider. The value specified for the Call-by-Call parameter sets the signaling value for
routing calls. The T1-PRI:PRI # Type and T1-PRI:NumPlanID parameters specify values that
the MAX unit applies to outbound calls on PRI lines so that the switch can properly interpret
the telephone number dialed.
To configure carrier-specific services, open the Net/T1 > Line Config profile > Line N
subprofile for the line you are configuring and set the following parameters:
Parameter
Call-by-Call
T1-PRI:PRI # Type
T1-PRI:NumPlanID NumberPlanID field in the called party's information element.
For detailed information about each parameter, see the MAX Reference.
Using MAXDAX
MAXDAX enables you to route incoming calls from T1 or PRI lines to specific outgoing
channels on the same or different T1 or PRI lines. To implement MAXDAX, you must set
parameters in the Net2Net Incoming Calls and Net2Net ChanGroup ID profiles. In the
Net2Net Incoming Calls profile, you define parameters used in configuring channels on which
the MAX unit receives incoming calls. In the Net2Net ChanGroup ID profile, you define
parameters used in configuring channels for outbound calls.
For complete information about MAXDAX, see "Configuring MAXDAX" on page 3-74. Or,
for detailed information about each parameter, see the MAX Reference.
3-10
A data service (voice, for example). Any call that uses the specified data
service will be routed to line 2. This parameter can be used as an
alternative to Ans # when the second line's signaling mode is PBX T1.
(For more information, see "Configuring inbound calls" on page 3-59
and "Configuring outbound calls" on page 3-69.)
Number (one or two) of sets of Goertzel samples the PRI-T1 conversion
process is to use for DTMF tone detection. By default, the MAX uses
only one sample to decode signals from robbed-bit PBXs, because some
PBX devices have a tone duration of less than 50ms, which does not
provide enough time to compute two sets of Goertzel samples. The
PRI-T1 conversion process is more accurate when the MAX can use two
samples. Using two samples is recommended when the tone duration is
longer than 70ms.
Specifies
Service provider's call-by-call signaling value for routing calls from a
local device to the carrier's network through the MAX unit.
TypeOfNumber field in the called party's information element.