Lucent Technologies MAX 6000 Network Configuration Manual page 277

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

The next set of parameters on MAX-42 specifies the circuit between its two Frame Relay
interfaces:
Ethernet
Connections
Ethernet
Connections
The following parameters on MAX-39 define the datalinks to MAX-42 and to the Pipeline
130:
Ethernet
Frame Relay
Ethernet
Frame Relay
MAX 6000/3000 Network Configuration Guide
max
Station=max
Active=Yes
Encaps=FR-Cir
Route IP=No
Encaps options
FR Prof=dce-max
DLCI=100
FR Circuit=cir-42
max39
Name=max39
Active=Yes
Encaps=FR-Cir
Route IP=No
Encaps options
FR Prof=nni-39
DLCI=200
FR Circuit=cir-42
nni-42
Name=nni-42
Active=Yes
FR Type=NNI
Nailed Grp=777
dce-p130
Name=dce-p130
Active=Yes
FR Type=dce
Nailed Grp=888
Configuring Frame Relay
Configuring the MAX as a Frame Relay switch
Preliminary January 4, 2001