Sample Radius Frame Relay Data Link Profile - Lucent Technologies MAX 6000 Network Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Configuring Frame Relay
Configuring 64 switched Frame Relay connections

Sample RADIUS Frame Relay Data Link profile

The following example profile corresponds to the user profile in "Sample RADIUS user
profile" on page 5-38:
SWITCHED-FR-DTE Password="ascend", User-Service=
Framed-User
You must set Ascend-Call-Type to Switched. Also, the Frame Relay Data Link
profile's name must match the value specified in the Ascend-FR-Profile-Name attribute
of the DNIS or CLID profile.
Sample RADIUS user profile
The following User profile enables the user switched-dte1 to access the destination
specified by route-My-MAX4000:
switched-dte1-out Password="ascend", User-Service=Dialout-Framed-User
Make sure that:
5-38
Preliminary January 4, 2001
Ascend-FR-Profile-Name="SWITCHED-FR-DTE",
Ascend-Call-Type=Switched,
Ascend-FR-Type=Ascend-FR-DTE,
Ascend-FR-Link-Mgt=Ascend-FR-T1-617D,
Ascend-FR-N391=6,
Ascend-FR-DTE-N392=3,
Ascend-FR-DTE-N393=4,
Ascend-FR-T391=10
User-Name="switched-dte1",
Ascend-Dial-Number=953757,
Framed-Protocol=FR,
Framed-Address=192.168.166.212,
Framed-Netmask=255.255.255.0,
Ascend-Route-IP=Route-IP-Yes,
Ascend-Metric=2,
Ascend-FR-DLCI=16,
Ascend-FR-Profile-Name="SWITCHED-FR-DTE",
Ascend-Bridge=Bridge-No,
Ascend-Call-Type=Switched,
Ascend-Data-Svc
Ascend-Idle-Limit=120
The value in User-Name matches the name specified in the associated Route profile.
The value in Ascend-FR-Profile-Name matches the name of the associated Frame
Relay Data Link profile.
You set Ascend-Call-Type to Switched.
=Switched-56K,