Following is a comparable RADIUS profile:
fiona Password = "localpw"
Note: The RADIUS profile must specify Ascend-Maximum-Channels, or the default value of
1 prevents the client from establishing a multichannel call.

Configuring a nailed/MP+ connection

A nailed/MP+ connection is a nailed connection that can add switched channels for increased
bandwidth. The MAX unit dials switched channels when it receives an outbound packet for the
far end and cannot forward it across the nailed connection, either because those channels are
down or because they are being fully utilized.
If both the nailed and switched channels in a nailed/MP+ connection are down, the connection
does not reestablish itself until the nailed channels are brought back up or you dial the switched
channels.
MAX 6000/3000 Network Configuration Guide
Encaps=MPP
Encaps Options
Send Auth=PAP
Send PW=remotepw
Aux Send PW=secondpw
Recv PW=localpw
Configure the DBA Monitor and the Lucent criteria for bandwidth management. For
example:
Encaps Options
DBA Monitor=Transmit-Recv
Base Ch Count=1
Min Ch Count=1
Max Ch Count=5
Inc Ch Count=1
Dec Ch Count=1
Dyn Alg=Quadratic
Sec History=15
Add Pers=5
Sub Pers=10
Target Util=70
Idle Pct=0
Note: For optimum performance, both sides of a connection must set the Base Ch Count,
Min Ch Count, and Max Ch Count parameters to the same values.
Exit the profile and, at the exit prompt, select the exit and accept option.
Service-Type = Framed-User,
Framed-Protocol = MPP,
Framed-IP-Address = 10.10.10.64,
Framed-IP-Netmask = 255.255.255.0,
Ascend-Base-Channel-Count = 1,
Ascend-Maximum-Channels = 5,
Ascend-DBA-Monitor = DBA-Transmit-Recv,
Ascend-Seconds-Of-History = 15,
Ascend-Add-Seconds = 5,
Ascend-Remove-Seconds = 10
Ascend-Target-Util = 70