combination is busy, the other gets the call. If both are busy, the longest idle among all ports in
Slots 6 and 5 gets the call and so on.

Numbering Plan profile

Numbering Plan profiles enable you to optimize the placement of outgoing calls. You can fine
tune the point at which the MAX assumes it has received all the dialed digits, and you can
provide callers with a more familiar dialing procedure. If you do not configure a Numbering
Plan profile, callers must either press the # key or wait the specified number of seconds set in
the POTS Digit Timeout parameter (System > Sys Config > POTS Digit Timeout) before the
unit places the call.
The Numbering Plan profiles are global to the system. The Numbering Plan profile menu, in
the System profile, supports up to 32 Numbering Plan profiles. The first Numbering Plan
profile is the default. The unit uses the default profile when no active profile matches the
dialed number. Each Numbering Plan profile includes the following parameters:
Parameter
Name
Active
Dial Prefix
Number Digits Exact number of digits in a phone number that has a prefix matching this
Routing outbound calls
The MAX routes an outgoing call initiated by the POTS device to a WAN T1/E1/PRI/BRI line.
For example, an analog phone could dial into a port on the MAXPOTS card and that call gets
routed out the T1 line:
Phone, or fax
You can route outbound (and inbound) calls by configuring the Call Routes profile. Examples
of Call Routes profiles follow. In addition, examples of MAXPOTS rollover functionality is
shown and a Numbering Plan profile.
Note: MAXPOTS supports both DTMF and pulse dialing (7.5 pps to 12 pps)
FDOO GLDOLQJ
Examples of Call Routes configurations
Following are four sample configurations. With the first configuration, the MAX automatically
prepends a trunk digit to each outbound call. With the second, it strips a trunk digit from each
outbound call. With the third and fourth configurations, the unit routes on the basis of area
code and call-setup parameters, respectively.
MAX 6000/3000 Network Configuration Guide
Configuring POTS capability on the MAX 6000 and MAX 3000
Specifies
Name of the profile.
This profile is available/not available for use.
Leftmost digits of the dialed phone number.
entry's Dial Prefix setting.
Analog
interface: FXS
MAX
Configuring Individual WAN Connections
WAN trunk: T1,
E1, PRI, BRI
WAN
IRU RXWERXQG
4-107