Magnetic Proximity Switch - ABB IRB 660 Product Manual

Flexgripper-vacuum
Hide thumbs Also See for IRB 660:
Table of Contents

Advertisement

2.5.3. Magnetic proximity switch

The magnetic proximity switch is located as shown in the figure below.
Position 1
Position 2
A
Position 1
Use this procedure to remove the magnetic proximity switch.
DANGER!
Turn off all electric power and pneumatic pressure supplies to the gripper!
3HAC040633-002 Revision: -
en1012013
en1012013
Magnetic proximity switch
Action
1. Loosen the small bolt.
2. Open the terminal box and remove the
cable.
3. Remove the magnetic proximity switch.
2 FlexGripper-Vacuum
2.5.3. Magnetic proximity switch
Note
en1012015
Parts: A: Small bolt
See the circuit diagram for details.
Continues on next page