ABB IRB 660 Product Manual page 114

Flexgripper-vacuum
Hide thumbs Also See for IRB 660:
Table of Contents

Advertisement

3 FlexGripper UI
3.3. Trouble shooting
Continued
Active view no valid test view
Description
Possible reason
Solution
Two many views
Description
Possible reason
Solution
Duplicated adress
Description
Possible reason
112
en1011075
The current test view is not a valid test view.
Enter Control panel->Flexpendant-> AdditionalTestView, check if the
test view of the FlexGripper UI is selected.
When all the 6 places of the task bar are occupied by views, a warning
message box will pop up when clicking on the GUI icon.
Too many views are opened at the same time.
Close one or more of the views not in use.
en1011075
Two I/O units with the same addresses name'BOARD10'.
Continues on next page
3HAC040633-002 Revision: -