Logging mode
In the Logging mode it is possible to check the
condition and the status of both the hardware
and the software.
There are three types of logging facilities, inter-
nal logging (Intern), External logging (Extern)
and technical error logging (Errors).
To step backwards or exit, press
Before you enter the Logging mode this is dis-
played:
MAINTENANCE SUPPORT SELECTION
Logging
Turn the set knob until the text "Logging" starts
blinking, confirm with
The actual information is shown on the informa-
tion display, which is divided into three fields
(0 - 2).
It is possible to choose any AK 95 S parameter
for any of the three fields.
See Logging mode flow diagram.
field 0
AK 95 / AK 95 S Service Manual
HCEN 9136 Rev. 10.2005
Service/Preset
field 1
field 2
Service Technicians Guide
4:25