Parameters
interval: Sets the LLDP trap transmission interval, in the range of 5 to 3600 seconds.
Description
Use lldp timer notification-interval to set the LLDP trap transmission interval.
Use undo lldp timer notification-interval to restore the default.
By default, the LLDP trap transmission interval is 5 seconds.
Examples
# Set the LLDP trap transmission interval to 8 seconds.
<Sysname> system-view
[Sysname] lldp timer notification-interval 8
lldp timer reinit-delay
Syntax
lldp timer reinit-delay delay
undo lldp timer reinit-delay
View
System view
Default level
2: System level
Parameters
delay: Sets the LLDP reinitialization delay, in the range of 1 to 10 seconds.
Description
Use lldp timer reinit-delay to set the LLDP reinitialization delay.
Use undo lldp timer reinit-delay to restore the default.
By default, the LLDP reinitialization delay is 2 seconds.
Examples
# Set the LLDP reinitialization delay to 4 seconds.
<Sysname> system-view
[Sysname] lldp timer reinit-delay 4
lldp timer tx-delay
Syntax
lldp timer tx-delay delay
undo lldp timer tx-delay
View
System view
Default level
2: System level