13.6
Timer 2 (Timer continues when COMPLETE flag is
ON) (M+M_TIMER2)
M+M_TIMER2
This function block is a clock timer. It continues to count the time even if the time count value exceeds the set value, and the
timer stops when the time count value reaches the timer high limit value.
FBD/LD
M+M_TIMER2
RUN
PRE_COMP
STP
COMP_
RST_
RS_START
Applicable tag type
TIMER2
Control mode
MAN
■Block diagram
Faceplate
RUN
RUN
STP
STOP
RST_
RESET
RS_START
RESET/START
13 STATUS TAG
470

13.6 Timer 2 (Timer continues when COMPLETE flag is ON) (M+M_TIMER2)

AUT
CAS
Count processing
RUN
STOP
RESET
RESET/START
Internal
clock
Tag data
CMV
M+M_TIMER2
Count RUN status
RESET/START
RUN
STOP
Count stop status
Preset value comparison
(PV ≥ PSV)
PV
PSV
SV
CSV
RESET
Count initialization
(count value → low limit
value)
RESET
Setting value comparison
(PV ≥ SV)
PRE_COMP
COMP_

Advertisement