Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 54

Process control function blocks
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■2 position ON/OFF Control (Disable Tracking for primary loop)
Function block symbol
M+P_ONF2
■3 position ON/OFF Control (Enable Tracking for primary loop)
Function block symbol
M+P_ONF3_T
■3 position ON/OFF Control (Disable Tracking for primary loop)
Function block symbol
M+P_ONF3
■Program Setter
Function block symbol
M+P_PGS
■Multi-Point Program Setter
Function block symbol
M+P_PGS2_
■Loop Selector (Disable Tracking for primary loop)
Function block symbol
M+P_SEL
■Loop Selector (Enable Tracking for primary loop only by CASIN_T)
Function block symbol
M+P_SEL_T1
■Loop Selector (Enable Tracking for primary loop by CASIN_T1/_T2)
Function block symbol
M+P_SEL_T2
■Loop Selector (Enable Tracking from secondary loop to primary loop)
Function block symbol
M+P_SEL_T3_
Special
The following FB changes the control mode.
■Change Control Mode
Function block symbol
M+P_MCHG
3 LISTS OF PROCESS CONTROL FUNCTION BLOCK
52
3.2 Tag Access FBs
Processing details
Performs two-position (on/off) control.
Processing details
Performs three-position (on/off) control. The primary loop can be tracked.
Processing details
Performs three-position (on/off) control.
Processing details
Registers time width sets and setting value programs of up to 16 steps, and outputs a setting value
corresponding to the progress time of each step with linear interpolation.
Processing details
Registers time width sets and setting value programs of up to 32 steps, and outputs a setting value
corresponding to the progress time of each step with linear interpolation.
Processing details
Selects an input value depending on the setting of the select signal and outputs the result. The
input 1 and 2 are not tracked.
Processing details
Selects an input value depending on the setting of the select signal and outputs the result. The
input 1 is not tracked. The primary loop of the input 2 is tracked, but tracking from the secondary
loop is not performed.
Processing details
Selects an input value depending on the setting of the select signal and outputs the result. The
primary loop of the input 1 and 2 is tracked, but tracking from the secondary loop is not performed.
Processing details
Selects two input values depending on the setting of the select signal and outputs the result. The
primary loop of the input 1 and 2 is tracked from the secondary loop.
Processing details
This function block switches the control mode to one of MANUAL, AUTO, CASCADE, COMPUTER
MV, COMPUTER SV, and CASCADE DIRECT according to a mode change signal.
Reference
Page 298 M+P_ONF2
Reference
Page 301
M+P_ONF3_T
Reference
Page 305 M+P_ONF3
Reference
Page 308 M+P_PGS
Reference
Page 312 M+P_PGS2_
Reference
Page 323 M+P_SEL
Reference
Page 326
M+P_SEL_T1
Reference
Page 330
M+P_SEL_T2
Reference
Page 334
M+P_SEL_T3_
Reference
Page 338 M+P_MCHG