Variable name
Description
LLAG_T1
First Order Lag: Delay Time (Sec)
PVCMP_EN
PV Compensation Execution condition
PVCMP_MODE
PV Compensation Mode
PV Compensation Execution condition
PVDCMP_EN
PID2H_MTD
Derivative Gain
PID2H_DVLS
Large Deviation Alarm Hysteresis
PID2H_PN
Reverse Action/Direct Action
PID2H_SVPTN_B0
Setting Value (SV) Used
PID2H_PVTRK_EN
PV Tracking Execution condition
PID2H_ISTP
Integration Stop Signal
PID2H_DSTP
Derivation Stop Signal
PID2H_LMT_ISTP
Stop Integration, when MV variation rate limiter
alarm occurred
PID2H_SVLMT_EN
SV High/Low Limiter
MV Compensation Execution condition
MVDCMP_EN
MV Compensation Mode
MVDCMP_MODE
MV Gain Correction Execution condition
MVDGAINCMP_EN
OUT3_NMAX
Output Conversion High Limit
OUT3_NMIN
Output Conversion Low Limit
OUT3_MVCMP_EN
MV Compensation Execution condition
OUT3_MVCMP_MOD
MV Compensation Mode
E
OUT3_PREMV_EN
Preset MV Execution condition
OUT3_PREMV_V
Preset MV Value (Unit: %)
OUT3_MVHLD_EN
MV Hold Execution condition
OUT3_MVTRK_EN
MV Tracking Execution condition
OUT3_STP_OTYPE
Output when loop or tag is stopped
OUT3_SEA_OTYPE
MV Output Selection when SEA is occurred
OUT3_ARW_EX_EN
MV Value Instantaneous Pullback
OUT3_MVPH
MV Internal Operation High Limit Value (Unit: %)
OUT3_MVPL
MV Internal Operation Low Limit Value (Unit: %)
OUT3_MVREV_EN
MV Reverse Execution condition
OUT3_FOTS_EN
Tight Shut/Full Open Execution condition
OUT3_MVFO
Output Value for Full Open (Unit: %)
OUT3_MVTS
Output Value for Tight Shut (Unit: %)
12.10 2-degree-of-freedom Advanced PID Control (Disable Tracking for primary loop) (M+M_2PIDH_)
Recommended range
Initial
value
0 to 999999[s]
1.0
TRUE: Execute
FALSE
FALSE: Stop
0: Addition
0
1: Replacement
TRUE: Execute
FALSE
FALSE: Stop
0 to 9999
8.0
0 to 100
2.0
0: Reverse action
0
1: Direct action
TRUE: Not used
TRUE
FALSE: Used
TRUE: Execute
FALSE
FALSE: Stop
TRUE: Execute
FALSE
FALSE: Stop
TRUE: Execute
FALSE
FALSE: Stop
TRUE: Stop
FALSE
FALSE: Not stop
TRUE: Execute
FALSE
FALSE: Not execute
TRUE: Execute
FALSE
FALSE: Stop
0: Addition
0
1: Replacement
TRUE: Execute
FALSE
FALSE: Stop
-999999 to 999999
100.0
-999999 to 999999
0.0
TRUE: Execute
FALSE
FALSE: Stop
0: Addition
0
1: Replacement
TRUE: Execute
FALSE
FALSE: Stop
0 to 100[%]
0.0
TRUE: Execute
FALSE
FALSE: Stop
TRUE: Execute
FALSE
FALSE: Stop
0: Hold
0
1: Preset value
0: Hold
0
1: Preset MV output
2: Neither hold nor preset MV
output is performed.
TRUE: Execute
FALSE
FALSE: Not execute
MH to 999999[%]
100.0
-999999 to ML[%]
0.0
TRUE: Execute
FALSE
FALSE: Stop
TRUE: Execute
FALSE
FALSE: Stop
100 to 125[%]
112.5
-25 to 0[%]
-16.82
Set by
Data type
User
REAL
User
BOOL
User
INT
User
BOOL
User
REAL
User
REAL
User
INT
User
BOOL
User
BOOL
User
BOOL
User
BOOL
User
BOOL
User
BOOL
User
BOOL
User
INT
User
BOOL
User
REAL
User
REAL
User
BOOL
User
INT
User
BOOL
User
REAL
User
BOOL
User
BOOL
User
INT
User
INT
User
BOOL
User
REAL
User
REAL
User
BOOL
User
BOOL
User
REAL
User
REAL
12 LOOP TAG