6.2 Wiring to GOT Power Section

This section provides an example for connecting power cables and ground cables to the power terminals
situated on the back of the GOT.
AC
Ground cables
6
6.2 Wiring to GOT Power Section
- 4
100/110V AC
Fuse
INPUT
100-240VAC
AC
DC
24V DC
INPUT
24VDC
Grounding
(1) Precautions for wiring to the power supply section
• For 100V AC, 200V AC or 24V DC cable, use the thickest cable as possible
2
(Max. 2mm
) and start twisting them at the position closest to the connected
terminals.
To prevent a short circuit due to loose screws, use the solderless terminal with
insulation sleeve.
• When connection is made between LG and FG terminals, be sure to connect
them to the ground.
Otherwise, the system becomes susceptible to noise.
Since the LG terminal has potential equal to a half of the input voltage, touching
the terminal may lead to an electric shock.
In the case of 100V AC
GOT
(LG)
(FG)
In the case of 24V DC
GOT
(LG)
(FG)
- +