Chapter 16 PLC Function ApplicationsMS300
16-6-4

Detailed explanation of applications commands

API
01
Bit device
X
Y
Notes on operand usage:
The S operand can designate P
MS300 series device: The S operand can designate P0-P63
API
02
Bit device
X
Y
Notes on operand usage:
No operand
A contact-driven command is not needed
CALL NOW 800-985-6929
http://www.deltaacdrives.com
CALL
P
Word device
M
K
H
KnX KnY KnM
S: Call subprogram pointer.
Write the subprogram after the FEND command.
The subprogram must end after the SRET command.
Refer to the FEND command explanation and sample content for detailed
command functions.
SRET
P
Word device
M
K
H
KnX KnY KnM
A contact-driven command is not needed. Automatically returns next
command after CALL command
Indicates end of subprogram. After end of subprogram, SRET returns to main
program, and executes next command after the original call subprogram CALL
command.
Refer to the FEND command explanation and sample content for detailed
command functions.
http://www.deltaacdrives.com

Call subprogram

S
16-bit command (3 STEP)
T
C
D
32-bit command
Flag signal: none

Conclusion of subprogram

16-bit command (1 STEP)
T
C
D
32-bit command
Flag signal: none
16-48