CALL NOW 800-985-6929
ID No.
Display
35
36
37
40
41
42
43
44
45
CALL NOW 800-985-6929
http://www.deltaacdrives.com
W-phase current error.
Corrective Actions
 Reboots the power.
 If fault code is still displayed on the keypad please return to the factory
CC (current clamp) hardware error.
Corrective Actions
 Reboots the power.
 If fault code is still displayed on the keypad please return to the factory.
OC hardware error.
Corrective Actions
 Reboots the power.
 If fault code is still displayed on the keypad please return to the factory.
Motor parameters auto tuning error.
Corrective Actions
 Check if motor wiring is correct or not.
 Check if motor capacity and parameters are correct or not.
 Try again.
PID loss (ACI).
Corrective Actions
 Check the wiring of the PID feedback.
 Check the setting of the PID parameters.
PG feedback error.
Corrective Actions
 Check if the setting of encoder parameter is correct when drive is in PG
feedback close-loop control.
PG feedback loss.
Corrective Actions
 Check the wiring of the PG feedback.
PG feedback stall.
Corrective Actions
 Check the wiring of the PG feedback.
 Check if the setting of PI gain and acceleration or deceleration is suitable.
 Return to the factory.
PG slip error.
Corrective Actions
 Check the wiring of the PG feedback.
 Check if the setting of PI gain and acceleration or deceleration is suitable.
 Return to the factory.