Low Current Setting Level; Low Current Detection Time; Treatment For Low Current - Delta MS300 Series User Manual

Standard compact drive
Hide thumbs Also See for MS300 Series:
Table of Contents

Advertisement

CALL NOW 800-985-6929
Parameter record method as follows:
06-17
06-18
06-19
06-20
06-21
06-22
06-63
06-64
06-65
06-66
06-67
06-68
06-69
06-70
※ By time record, it can be known that the last fault (Pr. 06-17) happened after the drive run for 4
days and 240 minutes.
 The drive will operate as the setting of Pr. 06-73 when output current is lower than the setting of
Pr. 06-71 and when low current exceeds detected time Pr. 06-72. This parameter can be used
with external multi-function output terminal 44 (for low current output).
 The low current detection function will not be executed when drive is at sleep or standby status.
CALL NOW 800-985-6929
http://www.deltaacdrives.com
th
The 4
error: ocA occurs after another 1000 minutes.
th
The 5
error: ocd occurs after another 1000 minutes.
th
The 6
error: ocn occurs after another 1000 minutes.
Then Pr. 06-17~06-22 and Pr. 06-63~06-70 recorded as follows:
st
nd
1
fault
2
fault
ocA
ocd
0
ocA
0
0
0
0
0
0
0
0
1000
560
0
1
0
1000
0
0
0
0
0
0
0
0
0
0

Low Current Setting Level

Settings
0.0 ~ 100.0 %

Low Current Detection Time

Settings
0.00 ~ 360.00 sec.

Treatment for Low Current

0 : No function
Settings
1 : Warn and coast to stop
2 : Warn and ramp to stop by 2
3 : Warn and operation continue
http://www.deltaacdrives.com
Chapter 12 Description of Parameter SettingsMS300
rd
th
3
fault
4
fault
ocn
ocA
ocd
ocn
ocA
ocd
0
ocA
0
0
0
0
120
1120
2
2
560
120
1
2
1000
560
0
1
0
1000
0
0
nd
deceleration time
12.1-06-23
Email: info@deltaacdrives.com
th
th
5
fault
6
fault
ocd
ocn
ocA
ocd
ocn
ocA
ocd
ocn
ocA
ocd
0
ocA
680
240
3
4
1120
680
2
3
120
1120
2
2
560
120
1
2
Factory Setting: 0.0