This parameter needs to use KPC-CC01 (optional).
Input point of the counter can be set by multi-function terminal MI6 as a trigger terminal (set
Pr. 02-06 to 23). When counting completed, the specified multi-function output terminal will be
activated (Pr. 02-13, Pr. 02-36, Pr. 02-37 is set to 18). Pr. 02-19 cannot be set to 0 at this time.
When displayed c5555, the drive has counted 5,555 times. If displayed c5555
value is 55,550 ~ 55,559.
This parameter needs to use KPC-CC01 (optional).
When the count value counts from 1 to attain this value, the corresponding multi-function output
terminal will be activated (Pr. 02-13, Pr. 02-36, Pr. 02-37 is set to 17). This parameter can be used
for the end of counting to make the drive runs from the low speed to stop.
Time series diagram is shown below:
Ext ernal counter trigger signal
(Output signal)
Multi-function output terminal
Attain count assigned
RY1 Pr.02-13=17
It is used to set the signal for the digital output terminals (DFM-DCM) and digital frequency output
(pulse, work period = 50 %). Output pulse per second = output frequency X Pr. 02-21.
CALL NOW 800-985-6929
http://www.deltaacdrives.com
Terminal Counting Value Attained (return to 0)
Settings
0~65500
Preliminary Counting Value Attained (not return to 0)
Settings
0~65500
Displayed value
[00-04=01]
[0 2 - 0 6 =2 3 ]
TRG
02-13, 02-14, 02-36, 02-37
Digital Output Gain (DFM)
Settings
1~55
Desired Frequency Attained 1
Settings
0.00~599.00 Hz
The Width of the Desired Frequency Attained 1
Settings
0.00~599.00 Hz
Desired Frequency Attained 2
Settings
0.00~599.00 Hz
http://www.deltaacdrives.com
Chapter 12 Description of Parameter SettingsMS300
02-20= 3
12.1-02-17
Email: info@deltaacdrives.com
Factory Setting: 0
, the actual count
Factory Setting: 0
1.0 msec
1.0 msec
The width of trigger signal
Factory Setting: 1
Factory Setting: 60.00 / 50.00
Factory Setting: 2.00