Chapter 12 Description of Parameter SettingsMS300
 This parameter determines the behavior when 4~20 mA signal is loss, when ACIc (03-29 = 0).
 When Pr. 03-29≠0, it means the voltage input to ACI terminal is 0~10V or 0~20mA. At this
moment, Pr. 03-19 will be invalid.
 When setting is 1 or 2, it will display warning code "ANL" on the keypad. It will be blinking until the
loss of the ACI signal is recovered.
 When the motor drive stops, the condition of warning does not exist, then the warning will
disappear.
Function Chart
Settings
0
Output frequency (Hz)
1
Frequency command (Hz)
2
Motor speed (Hz)
3
Output current (rms)
4
Output voltage
5
DC BUS voltage
6
Power factor
7
Power
9
AVI
10
ACI
12
Iq current command
13
Iq feedback value
14
Id current command
15
Id feedback value
CALL NOW 800-985-6929
http://www.deltaacdrives.com

Signal Loss Selection of Analog Input 4-20 mA

Settings
0: Disable
1: Continue operation at the last frequency
2: Decelerate to 0 Hz
3: Stop immediately and display ACE

Multi-function Output 1 (AFM)

Settings
0~23
Functions
http://www.deltaacdrives.com
Descriptions
Max. frequency Pr. 01-00 is regarded as 100 %.
Max. frequency Pr. 01-00 is regarded as 100 %.
Max. frequency Pr. 01-00 is regarded as 100 %
(2.5 X rated current) is regarded as 100 %
(2 X rated voltage) is regarded as 100 %
450V (900V) = 100 %
-1.000~1.000 = 100 %
(2 X rated voltage) is regarded as 100 %
0~10 V = 0~100 %
4~20 mA = 0~100 %
(2.5 X rated current) is regarded as 100 %
(2.5 X rated current) is regarded as 100 %
(2.5 X rated current) is regarded as 100 %
(2.5 X rated current) is regarded as 100 %
12.1-03-14
Email: info@deltaacdrives.com
Factory Setting: 0
Factory Setting: 0
Email: info@deltaacdrives.com