CALL NOW 800-985-6929
This parameter is used to set the level of motor at zero-speed. When the actual speed is lower
than this setting, the corresponding multi-function output terminal which is set to 43 will be ON,
as shown below:
For Example:
If Pr. 02-50 displays 0034h (Hex), i.e. the value is 52 (decimal), and 110100 (binary). It means
MI3, MI5 and MI6 are ON.
Weights
Bit
For Example:
When Pr. 02-51 displays 000Bh (hex), i.e. the value is 11 (decimal), and switched to 1011 (binary)
which means RY. MO1 is at ON status.
Weights
Bit
0=ON
1=OFF
CALL NOW 800-985-6929
http://www.deltaacdrives.com
a ctua l mo tor
sp ee d
0 2- 47
MO =d 43
Display the Status of Multi-function Input Terminal
Settings
Monitor the status of multi-function input terminals
Weights
Weights
Bit
0=ON
1=OFF
Status of Multi-function Output Terminal
Settings
Monitor the status of multi-function output terminals
http://www.deltaacdrives.com