Delta MS300 Series User Manual page 184

Standard compact drive
Hide thumbs Also See for MS300 Series:
Table of Contents

Advertisement

CALL NOW 800-985-6929
Pr.
14-69
IGBT temperature at malfunction 6
14-70
Fault record 7
14-71
Fault record 8
14-72
Fault record 9
14-73
Fault record 10
Over-torque detection selection
14-74
(motor 3)
14-75
Over-torque detection level (motor 3)
14-76
Over-torque detection time (motor 3)
Over-torque detection selection
14-77
(motor)
14-78
Over-torque detection level (motor 4)
14-79
Over-torque detection time (motor 4)
Electronic thermal relay selection 3
14-80
(motor 3)
Electronic thermal relay action time 3
14-81
(motor 3)
Electronic thermal relay selection 4
14-82
(motor 4)
Electronic thermal relay action time 4
14-83
(motor 4)
CALL NOW 800-985-6929
http://www.deltaacdrives.com
Explanation
http://www.deltaacdrives.com
Chapter 11 Summary of Parameter SettingsMS300
Settings
o
-3276.7~3276.7
C
Refer to fault record Pr. 6-17~06-22
Refer to fault record Pr. 6-17~06-22
Refer to fault record Pr. 6-17~06-22
Refer to fault record Pr. 6-17~06-22
0: No function
1: Continue operation after Over-torque detection
during constant speed operation
2: Stop after Over-torque detection during constant
speed operation
3: Continue operation after Over-torque detection
during RUN
4: Stop after Over-torque detection during RUN
10~250 % (100 % corresponds to the rated current
of the drive)
0.0~60.0 sec.
0: No function
1: Continue operation after Over-torque detection
during constant speed operation
2: Stop after Over-torque detection during constant
speed operation
3: Continue operation after Over-torque detection
during RUN
4: Stop after Over-torque detection during RUN
10~250 % (100 % corresponds to the rated current
of the drive)
0.0~60.0 sec.
0: Inverter motor (with external forced cooling)
1: Standard motor (motor with fan on the shaft)
2: Disabled
30.0~600.0 sec.
0: Inverter motor (with external forced cooling)
1: Standard motor (motor with fan on the shaft)
2: Disabled
30.0~600.0 sec.
11-47
Email: info@deltaacdrives.com
Factory
Setting
Read
only
0
0
0
0
0
120
0.1
0
120
0.1
2
60.0
2
60.0
Email: info@deltaacdrives.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents