Application Selection - Delta MS300 Series User Manual

Standard compact drive
Hide thumbs Also See for MS300 Series:
Table of Contents

Advertisement

CALL NOW 800-985-6929
13 Macro / User Define Macro
 Note: After selecting the macro, some of default values will be adjusted automatically according
to the application selection.
 Group setting 02: Compressor
The following table of contents is the relevant application parameters used for compressor
settings.
Pr.
00-11
00-16
00-17
00-20
00-21
00-22
00-23
01-00
01-01
01-02
01-03
01-04
01-05
01-06
01-07
01-08
01-11
01-12
01-13
03-00
03-01
05-01
05-03
05-04
CALL NOW 800-985-6929
http://www.deltaacdrives.com

Application Selection

Settings
00: Disabled
01: User parameter
02: Compressor
03: Fan
04: Pump
05: Conveyor
06: Machine tool
07: Packing
08: Textiles
Explanation
Control of speed mode
Load selection
Carrier frequency
Source of the master frequency command (AUTO)
Source of the operation command (AUTO)
Stop method
Control of motor direction
Max. operation frequency of motor 1
Output frequency of motor 1
Output voltage of motor 1
Mid-point frequency 1 of motor 1
Mid-point voltage 1 of motor 1
Mid-point frequency 2 of motor 1
Mid-point voltage 2 of motor 1
Min. output frequency of motor 1
Min. output voltage of motor 1
Output frequency lower limit
Accel. time 1
Decel. time 1
Analog input selection (AVI)
Analog input selection (ACI)
Full-load current of induction motor 1 (A)
Rated speed of induction motor 1 (rpm)
Pole number of induction motor 1
http://www.deltaacdrives.com
Chapter 12 Description of Parameter SettingsMS300
0 (V/F control mode)
0 (Normal load)
Factory default setting
2 (External analog input)
1 (External terminals)
0 (Ramp to stop)
1 (Disable reverse)
Factory default setting
Factory default setting
Factory default setting
Factory default setting
Factory default setting
Factory default setting
Factory default setting
Factory default setting
Factory default setting
20 (Hz)
20 (s)
20 (s)
0 (No function)
1 (Frequency command)
Factory default setting
Factory default setting
Factory default setting
12.1-13-1
Email: info@deltaacdrives.com
Factory Setting: 00
Settings
Email: info@deltaacdrives.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents