Chapter 12 Description of Parameter SettingsMS300
 This parameter is used to set the function of multi-function terminals.
Summary of function settings
(Take N.O. normally open contact for example, ON: contact is closed)
Settings
0
No Function
1
Indication during RUN
Operating speed
2
attained
Desired frequency
3
attained 1 (Pr. 02-22)
Desired frequency
4
attained 2 (Pr. 02-24)
Zero speed (frequency
5
command)
Zero speed, include
6
STOP (frequency
command)
7
Over torque 1
8
Over torque 2
9
Drive is ready
10
Low voltage warn (LV)
CALL NOW 800-985-6929
http://www.deltaacdrives.com
40: Speed attained (including Stop)
42: Crane function
43: Motor actual speed output < Pr. 02-47
44: Low current output (Pr. 06-71 to Pr. 06-73)
45: UVW magnetic contactor ON / OFF switch
46: Master dEb signal output
50: Output for CANopen control
52: Output for communication card control
66: SO output logic A
67: Analog input level reached output
68: SO output logic B
73: Over torque 3
74: Over torque 4
Functions
Output terminal with no function
Active when the drive is not at STOP.
Active when output frequency of drive reaches to the setting
frequency.
Active when the desired frequency (Pr. 02-22) is attained.
Active when the desired frequency (Pr. 02-24) is attained.
Active when frequency command = 0. (the drive must be at RUN
status)
Active when frequency command = 0 or stops.
Active when the drive detects over-torque. Pr. 06-07 is for setting
the over-torque detection level (motor 1), and Pr. 06-08 is for
setting over-torque detection time (motor 1).
Refer to Pr. 06-06~06-08.
Active when the drive detects over-torque. Pr. 06-10 is for setting
the over-torque detection level (motor 2), and Pr. 06-11 is for
setting over-torque detection time (motor 2).
Refer to Pr. 06-09~06-11.
Active when the drive is ON with no abnormality detected.
Active when the DC Bus voltage is too low.
(refer to Pr. 06-00 low voltage level)
http://www.deltaacdrives.com
Descriptions
12.1-02-12
Email: info@deltaacdrives.com