Chapter 12 Description of Parameter SettingsMS300
 This parameter selects the functions for each multi-function terminal.
 When Pr. 02-00 = 0, multi-function options can be set by multi-function input terminal MI1, MI2.
 When Pr. 02-00 ≠ 0, specify the use of multi-function input terminals MI1, MI2 with reference to
the setting value of Pr. 02-00.
Example:
If Pr. 02-00 = 1: multi-function input terminal MI1 = FWD / STOP,
If Pr. 02-00 = 2: multi-function input terminal MI1 = RUN / STOP,
 When multi-function input terminal MI7 = 0, MI7 is designated as pulse input terminal.
 If Pr. 02-00 is set to 3-wire operation control, terminal MI3 is for STOP contact. The function set
will be invalid automatically.
Summary of function settings
(Take the N.O. normally opened contact for example, ON: contact is closed, OFF: contact is open)
Settings
0
No Function
Multi-stage speed
1
command 1 / multi-stage
position command 1
Multi-stage speed
command 2 / multi-stage
2
position command
2multi-stage
Multi-stage speed
3
command 3 / multi-stage
position command 3
Multi-stage speed
command 4 / multi-stage
4
position command 4
5
Reset
JOG operation
6
KPC-CC01 required
(optional)
CALL NOW 800-985-6929
http://www.deltaacdrives.com
multi-function input terminal MI2 = REV / STOP.
multi-function input terminal MI2 = FWD / REV.
Functions
15-stages speed or 15 positions could be set by the digital status
of these 4 terminals. 16-steps speed could be operate if the
master speed is included when setting as 15 steps speed. (Refer
to Parameter 04)
Use this terminal to reset the drive after the error of the drive is
eliminated.
This function is valid when the source of operation command is
external terminals.
The JOG operation executes when the drive stops completely.
During running, the operation direction can be changed, and
STOP key on the keypad is valid. Once the external terminal
receives OFF command, the motor will stop by the JOG
deceleration time. Refer to Pr. 01-20~01-22 for details.
01-07
Min. output frequency
http://www.deltaacdrives.com
Descriptions
01-22
JOG frequency
JOG accel. time
01-20
MIx-GND
Mix: external terminal
12.1-02-4
Email: info@deltaacdrives.com
JOG decel. time
01-21
OFF
ON
Email: info@deltaacdrives.com