Delta BX6.3 DD Operation And Installation Manual

Delta BX6.3 DD Operation And Installation Manual

Residential battery storage system
Hide thumbs Also See for BX6.3 DD:

Advertisement

Quick Links

Residential Battery storage system
BX6.3_DD
Operation and Installation Manual
www.deltaww.com

Advertisement

Table of Contents
loading

Summary of Contents for Delta BX6.3 DD

  • Page 1 Residential Battery storage system BX6.3_DD Operation and Installation Manual www.deltaww.com...
  • Page 3: Table Of Contents

    ......  3.6  Delta Inverter Connection ......
  • Page 4 ....Figure 2-1 : The DELTA BX6.3_DD Series have 2 models ......
  • Page 5: 1 Safety

    DELTA ELECTRONICS, INC. Service engineers and end users may not divulge the information contained herein or use this manual for purpose other than those strictly connected with correct use of the product.
  • Page 6: General Safety

    The battery storage system can be charged/discharged from grid, and provides electricity to household loads and electricity supply backup is available. The DELTA BX6.3_DD Battery storage system is NOT to be used as a backup for any medical uses or life supporting uses.
  • Page 7: Symbols

    Safety 1.2.2 Symbols This section describes the definition of the symbols in this manual. In order to prevent both personal injury and property damage, and to ensure long-term operation of the product, please read this section carefully and follow all the safety instructions while you use the product. DANGER! - This warning indicates an immediate hazard which will lead to death or serious injury may occur.
  • Page 8: Safety Instructions

    Safety 1.2.3 Safety Instructions The battery storage system should not be installed in direct sunlight or on flammable surfaces. Please be sure to mount the battery storage system tightly on a solid / smooth surface. The optimal temperature range for the battery storage system to operate is 10 to 30°C .
  • Page 9 Safety DANGER! - This warning indicates an immediate hazard which will lead to death or serious injury may occur. (1) Electrical Shock Do not touch the terminals of the battery module without protectors. Be grounded with the specified conditions. High voltage may occur between the positive and the negative terminals. Electric shock impairs health or may cause threat to life.
  • Page 10 Safety (6) Direct Connection Do not connect the battery module to AC power or unspecified DC power. This may cause the battery module's damage to leak electrolyte, generate heat, smoke, catch fire, or explode. (7) Use in Other Equipment Do not use the battery module for any other purposes or connecting unspecified equipment.
  • Page 11 Safety WARNING ! - This warning indicates a possible hazard which may lead to death or serious injury may occur. (1) Magnetism Do not place the battery module near strong magnetism. (e.g., electromagnetic cooker, etc. ) This may cause the battery module's damage to leak electrolyte, generate heat, smoke, catch fire, or explode.
  • Page 12: 2 Introduction

    • DELTA BX6.3_DD • DELTA BX6.3_DD + BX6.3_EX100 The DELTA BX6.3_DD Series have 2 models as shown in Figure 2-1. Delta reserves the right to make modifications to the content and technical data in this user manual without prior notice.
  • Page 13: Additional Information

    Introduction Distribution Panel Solar Panel Grid For AU market BX6.3_EX100 BX6.3_DD Washing Rice Microwave Chargeing Refrigerator Light Machine Cooker Critical Load Load MyDeltaSolar Cloud Service (Monitoring) Ethernet Cloud Data Collector MyDeltaSolar (Admin) 3rd Party Production: Feed-in: Monitoring Plaform 3 kW 1 kW Consumption: Purchased:...
  • Page 14: Product Overview

    Introduction 2.4 Product Overview The shipping components of DELTA BX6.3_DD are shown as Figure 2-3. ② ③ ④ ⑤ ① ⑥ ⑦ ⑧ ⑨ Figure 2-3 : Shipping Components Table 2-1 : Packing list Object Description Delta BX6.3_DD Residential DC ESS...
  • Page 15 Introduction Figure 2-4 shows the dimensions of DELTA BX6.3_DD. Figure 2-5 shows the details of interface. unit: mm Figure 2-4 : Dimensions It is prohibited to open the front door. It may cause failure. The warranty is void once the door is opened.
  • Page 16 Introduction Please refer to Figure 2-6 for the location of product label. You can identify the model number and the specifications by the information on the product label. The table (Table 2-3) along with these labels explains the definition of the specific mark.
  • Page 17: Led Indicators

    Introduction 2.5 LED Indicators The DELTA BX6.3_DD has three different color LED notification on the front cover of the case that signal various system statuses: Table 2-4 : LED Indicators LED Status Definition GREEN FLASH Standby mode ORANGE ON Charge...
  • Page 18: 3 Installation

    Installation 3 Installation WARNING ! - Do not install BX6.3_DD near or on flammable surfaces. - Please mount BX6.3_DD tightly on a solid / smooth surface. - Install BX6.3_DD in a location that prevents damage from flooding. - Do not expose BX6.3_DD to ambient temperatures above 60°C or below -10°C. - Operating or storing BX6.3_DD in temperatures outside its specified range might cause damage to BX6.3_DD.
  • Page 19: Unboxing And Review

    Installation 3.2 Unboxing and Review The unpacking procedure of BX6.3_DD is shown as Figure 3-1. ① ② ③ ③ Require two or more persons to move the battery inverter. There is an optional handle to easily stand up BX6.3, please see section 3.3 for detail.
  • Page 20 Installation Handle position Cabling area Prohibit to force with the cabling area. Require two or more persons to move the battery inverter. Figure 3-2 : General handling method...
  • Page 21: Handle (Optional)

    Installation 3.3 Handle (optional) Step 1 ① ② ① Step 2 ③ Handle position ② Prohibit to force with the cabling area. Figure 3-3 : Handling with optional transport handle...
  • Page 22 Installation Step 3 Handle position Cabling area Prohibit to force with the cabling area. Require two or more persons to move the battery inverter. Please lock screw (0.5N • m) plugs on the case after installation to avoid water inflow. ①...
  • Page 23: Mechanical Installation

    ATTENTION - Please check the space for installation which meets the recommended location. - Remember that DELTA will in not responsible for damage resulting from - BX6.3_DD falling due to insufficient mounting strength. This battery storage system is designed to stand on the floor fixed.
  • Page 24 Installation CAUTION ! >500 mm (max.:10m) - The optimal temperature range for BX6.3_DD and BX6.3_EX100 to operate is -10° to 45°C. Figure 3-6 : Recommended installation space with inverter Please keep enough space for wiring and pipping. (Max.: 400 mm) Figure 3-7 : Recommended installation space of BX6.3_DD + BX6.3_EX100...
  • Page 25 Installation The recommended spacing to wall is 100mm, please be sure the minimum space should more than 30mm. Be sure to select the flat floor surface for installation and strength can afford storage system weight. The Power ON/OFF button is located at the left side of BX6.3_DD, please make sure enough space is reserved to access this button.
  • Page 26 Installation It is recommended to install the wiring cover to prevent users from touching the electric cables. There are 5 conduit holes with defined number and the recommended screw torque/ PF pipe type are shown in Figure 3-9, please follow the instruction below to install: - Conduit hole NO.1: For the push button operation.
  • Page 27: Assemble Dc Connectors

    BX series uses Amphenol H4 connectors which provide along with the package of BX6.3_EX100 are genuine parts that are certified the quality and reliable from DELTA. Please follow the below requirements to choose the DC cable and crimp. - DC cable must choose the cooper conductor which insulation is above 600V withstands voltage.
  • Page 28: Delta Inverter Connection

    Installation 3.6 Delta Inverter Connection BX6.3_DD must connect with Delta inverters to construct a hybrid energy system. It can be integrated with different inverter model. For H5E_220 model, the cable connection is shown in Figure 3-10. Please follow the installation procedure below: 1.
  • Page 29: Battery Pack Expansion

    - Please check the battery pack regularly. If there are any impaired or loose parts, please contact your installer. Ensure that there are no fallen objects. DELTA BX6.3_DD can be added at most one extra battery pack to increase capacity. The battery expansion can be achieved by 1.
  • Page 30: Pe Connection

    Installation 3.8 PE Connection To ground the inverter, please ensure the PE conductor to the grounding point. Recommended specifications:4mm² - 6mm² Figure 3-12 : PE Wiring...
  • Page 31: 4 Maintenance

    Maintenance 4 Maintenance DANGER : ELECTRICAL HAZARD!! - Before any maintenance, please make sure you are well insulated to avoid risk of electric shock. In order to ensure the normal operation of inverter, please check and clean the unit regularly. Once there are any impaired or loose parts, please contact your inverter installer.
  • Page 32: 5 Error Message And Trouble Shooting

    Error message and Trouble Shooting 5 Error message and Trouble Shooting Table 5-1 : Error Message ERROR Code Message Cause Action Check the grid frequency. If grid frequency is not in acceptable range, Grid frequency over the limit of contact the utility operator to modify it. AC Freq High electricity regulation.
  • Page 33 Check the insulation of DC wiring. Insulation BT to ground Impedance in For Delta cloud registered user, system will (Insulation send alarm message to your e-mail when either input < 550 kohm Fault)
  • Page 34 Error message and Trouble Shooting Table 5-2 : Fault Message Fault Code Message Cause Action Check the power supply line for direct DC component in grid current current. DC Injection Contact the utility operator to improve the over the limit grid quality.
  • Page 35 Error message and Trouble Shooting Fault Code Message Cause Action HW COMM2 Internal fault (Red COMM Contact your inverter supplier. Fault) HW COMM1 Internal fault (DSP COMM Contact your inverter supplier. Fault) Ground Cur. Residual current over the limit (Ground Cur. Check the insulation of DC wiring.
  • Page 36 Error message and Trouble Shooting Fault Code Message Cause Action HW ZC Fail Internal fault Contact your inverter supplier. (ZC Circuit Fault) BT OVP Battery system internal fault Contact your inverter supplier. BT UVP Battery system internal fault Contact your inverter supplier. BT OTP Battery system internal fault Contact your inverter supplier.
  • Page 37: 6 De-Commissioning

    De-Commissioning 6 De-Commissioning WARNING ! - To avoid injuries, please follow the procedures to unload the inverter. If it is necessary to put the device out of operation for maintenance or storage, please follow the procedures below: At inverter side: 1.
  • Page 38: 7 Technical Data

    Technical Data 7 Technical Data Table 7-1 : Specifications for BX6.3 _ DD Model BX6.3_DD BX6.3_DD + BX6.3_EX100 GENERAL Enclosure Aluminum with powder coating Operating temperature -10℃ * ~ 45℃ Operating Altitude 0 to 2000m (0 to 6666 ft.) Relative humidity 0% –...
  • Page 39 Technical Data Model Listing Model Inverter Battery Wi-Fi BX6.3_DD (BX6.3_DD) BX6.3_DD + BX6.3_EX100 (BX6.3_DD + BX6.3_EX100) * BX6.3_EX100 (BX6.3_EX100) * BX6.3_EX100 can only be used with the BX6.3_DD / BX6.3_AC100.
  • Page 40 Version 220720...

Table of Contents