Ricoh M0A0 Service Manual page 102

Table of Contents

Advertisement

2.Installation
Center GUI.
6.
Execute the registration with SP5816-206.
7.
Check the registration result using SP5816-207.
Value
0
Succeeded
2
Already registered
3
Communication error (proxy enabled)
4
Communication error (proxy disabled)
5
Proxy error (Illegal user name or password)
8
Other error
9
Request number confirmation executing
10
Request number error (The applicable device was not registered when
moving the machine was requested.)
11
Request number error (Data is already registered under this number.)
12
Request number error (invalid parameter)
8.
Exit the SP mode.
SP5816-208 Error Codes
Cause
Operation Error,
Incorrect Setting
90
Meaning
Code
-
An Inquiry or registration attempted
12002
without acquiring a request number.
-
Attempted registration without execution
12003
of a confirmation and no previous
registration.
-
Attempted setting with illegal entries for
12004
certification and ID2.
-
@Remote communication is prohibited.
12005
The device has an Embedded RC gate-
related problem.
-
A confirmation request was made after
12006
the confirmation had been already
completed.
-
The request number used at registration
12007
was different from the one used at
confirmation.
Meaning
Solution/ Workaround
-
Check the registration status.
Check the network condition.
Check the network condition.
Check Proxy user name and
password.
See "SP5816-208 Error
Codes" below.
Processing... Please wait.
-
Check the request number
again.
Check the request number
again.
Solution/ Workaround
Obtain a Request Number
before inquiry or registration.
Perform Confirmation before
attempting registration.
Check ID2 of the machine.
Make sure that "Remote Service"
in User Tools is set to "Do not
prohibit".
Execute registration.
Check the request number.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp 402spf

Table of Contents