4.Service Tables
1: Enabled
3-
Not used
4
5
PSTN dial-in routing setting
0: OFF
1: ON
6
Not used
7
Action when there is no box with an F-
code that matches the received SUB
code
0: Disconnect the line
1: Receive the message
(using normal reception mode)
Communication Switch 18 (SP No. 1-104-025)
No
Function
0-4
Not used
5
IP-Fax dial-in routing selection
0: Off
1: On
6
PSTN 2 dial-in routing
0: Off
1: On
7
PSTN 3 dial-in routing
0: Off
1: On
Communication Switch 19 - Not used (do not change the settings)
Communication Switch 1A - Not used (do not change the settings)
Communication Switch 1B (SP No. 1-104-028)
No
Function
0-
Extension access code (0
7
to 7) to turn V.8 protocol
On/Off
0: On
1: Off
68
Do not change the settings.
1: The machine sets multiple PSTN dial-in numbers in the PSTN dial-
in line and transfers received data from each PSTN dial-in number to
each address.
Do not change the settings.
Change this setting when the customer requires.
Comments
Do not change the settings.
1: Transfers received data to each IP-Fax dial-in number.
IP-Fax dial-in number is a 4-digit number.
Enables or disables dial-in routing for the PSTN 2 connection.
Enables or disables dial-in routing for the PSTN 3 connection.
Comments
If the PABX does not support V.8/V.34 protocol procedure, set this bit to "1" to
disable V.8.
Example: If "0" is the PSTN access code, set bit 0 to 1. When the machine detects
"0" as the first dialed number, it automatically disables V.8 protocol.
(Alternatively, if "3" is the PSTN access code, set bit 3 to 1.)
Need help?
Do you have a question about the M0A0 and is the answer not in the manual?
Questions and answers