SC277-10
D
SC300 (Image Processing – 1)
SC No.
Level
SC302
D
High voltage output error: Charge unit /Development unit
This SC is issued if the BiCU detects a short in the power pack 10 times consecutively.
Short circuit (-)
SC No.
Level
SC332-
D
Toner supply feed lock
00
Under the condition that the Toner Cartridge has not reached the end, an error that no toner is
supplied has been detected over n times in succession.
n: The value was specified at SP2-931-005.
Error Name/Error Condition/Major Cause/Solution
Replace the LED head.
Replace the BiCU.
Error Name/Error Condition/Major Cause/Solution
LEDA communication error
The head type data was read three times in succession
Loosen or disconnect of FFC between the BiCU and LED array
Defective FFC between the BiCU and LED array
Defective ASIC
Turn the main power OFF and then ON.
Check and connect the FFC.
Replace the FFC between the BiCU and LED array.
Replace the BiCU.
Error Name/Error Condition/Major Cause/Solution
Replace the controller board.
Check the connector connection.
Error Name/Error Condition/Major Cause/Solution
Overloaded toner feeding system (toner clogging)
Detection screw of the PCDU not rotating
Failure in the sensing element (sensor): Light leak
Failure in the toner supply pawl
Failure in the toner supply clutch
Replace the Toner Cartridge.
Replace the PCDU