Ericsson AVP 1000 Reference Manual page 59

Table of Contents

Advertisement

Note: The unit can be configured to simultaneously provide either the same TS
1. Navigate to the Service Configuration web page.
2. Expand the Host Outputs node in the Outputs widget, and click on the required
Note: The Satellite Modulator Output Stream 1 and Satellite Modulator Output
3. Create a Transport Stream by right clicking on the required output and selecting
Figure 3.5
4. Adjust the Transport Stream properties as required.
EN/LZT 790 0023/1 R16A
over multiple outputs (e.g. where additional output option cards are fitted) or
different TS and the various available outputs. See section 3.8.9 for
information on copying a TS.
output. A blue box is drawn around the selected item and the properties
associated with it are displayed in the Transport Stream accordion panel of the
Properties widget.
Stream 2 outputs behave somewhat differently than the other outputs.
When selected, the parameters from the Device Configuration >
Advanced Video Processor Settings > Encode > Slot n – Satellite
Modulator Option Card > Satellite Modulator Option Card > Modulation
Parameters, Output Parameters and Input Parameters are shown to
ease access and reduce the time needed for setting up the unit. The Input
Parameters tab is shown to allow easy access to the RAS encryption
setting. All other parameters on this tab should be left at their default values.
For other outputs, an empty page is shown in the Properties widget if no
Transport Stream exists under them. Otherwise, the Transport Stream
properties are displayed.
the Add Transport Stream command from the context menu, as shown in
Figure 3.5. The properties of the newly created Transport Stream appear in the
Properties widget.
Service Configuration Web Page – Adding a Transport Stream
Getting Started
3-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avp 2000Avp 1000 1ruAvp 3000Avp 1000 seriesAvp 1000 1ru seriesAvp 2000 series ... Show all

Table of Contents