Ericsson AVP 1000 Reference Manual page 227

Table of Contents

Advertisement

Parameter
Values
AR Signalling Output
Off, AFD Only, AFD and Bar Data
Control
TC Output Location
Off, SEI Message
Video Component
The parameters listed in are available on the Component tab of the Properties widget on
the Service Configuration page when a video component is selected in the Outputs
widget. The same parameters can be accessed through the Output/<output
name>/Transport Stream ID: <n>/Service List/<service name>/Component List/Slot
<x> Video Stream on PID <y> menu on the front panel.
Table 5.14 Video Component Parameters
Parameter
Values
PID
32 to 8190
Bit Rate Weighting
Fixed, Minimum, 2 to 20
Master TS
Off, On
Source PID Monitoring
Off, On
Vertical Blanking Interval / Ancillary Data
The parameters listed in the table below are available on the VBI tab of the Properties
widget on the Service Configuration page when a video stream is selected in the Outputs
widget. The same parameters can be accessed through the Advanced/CE-a/Video/Video
1/Input/VBI Extraction menu on the front panel.
Table 5.15 Vertical Blanking Interval / Ancillary Data Parameters
Parameter
Values
Enable VBI Pass-thru
Off, On
Mode
Description Control
VBI Descriptor Mode
Standard, Legacy, Philips, User
VBI Data Descriptor
Off, On
Insertion
VBI Teletext
Off, On
Descriptor Insertion
Teletext Descriptor
Off, On
Insertion
EN/LZT 790 0023/1 R16A
Description
Controls which source is used for embedding aspect ratio
signaling into user data. If set to Off, no aspect ratio data
will be resent in the output. AFD sources are: SMPTE
2016, Video Index, WSS-AFD/WSS, user set Aspect
Ratio. Bar Data is only SMPTE 2016.
Defines how timecode is put into the output video stream.
Description
Sets the packet identifier associated with the component.
Specifies the weight associated to the component in the
Bit Rate Tracking algorithm.
Sets the master Transport Stream for the component.
Priority 1 ETR290 monitoring on this PID from an IP input
can be enabled, and can be set to caused a redundancy
switch to a spare device if in a system controlled by
Ericsson control software. Not supported in this release.
Description
Enable Pass-thru of VBI, ANC and Teletext data from
specified PIDs, instead of extracting them from SDI. Read
only parameter. Not supported in this release.
The source for Closed Captions data encoded as part of
the Video Stream (only applicable when Video Frame Rate
is 29.97 Hz)
Controls if the VBI Data Descriptor is inserted into the
PMT. Available only if VBI Descriptor Mode is set to User.
Controls if the VBI Teletext Descriptor is inserted into the
PMT. Available only if VBI Descriptor Mode is set to User.
Controls if the Teletext Descriptor is inserted into the PMT.
Available only if VBI Descriptor Mode is set to User.
Web GUI Control
5-51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avp 2000Avp 1000 1ruAvp 3000Avp 1000 seriesAvp 1000 1ru seriesAvp 2000 series ... Show all