Ericsson AVP 1000 Reference Manual page 205

Table of Contents

Advertisement

Table 5.6
Splicing Set Up Options
Parameter
Values
SCTE 104 Channel
None, ChannelA to ChannelP
GPI Pin Triggered
Open, Closed (Default)
Polarity
Out Pre-roll
0, 4 to 100(s)
Return Pre-roll
0, 4 to 100(s)
Return to Network
Automatic
External Control
Splice Duration
1 to 10000 (s)
Fixed Delay
0 to +1000 (ms)
Splice ID Increment
For each Avail, For each Msg
Mode
Avail_Descriptor
Off (Default), Present
Provider Avail Id
0 to 424967295
GPI Input Pin State
5.4.4.4.5
Setting Up the VCM to Use GPI Inputs
Note: It is not possible to define the EventID , so all SCTE-35 messages will
The example given here shows setting up a CE-x in slot 3.
To set Up the VCM to use GPI inputs, select the Advanced Setup tab on the
Device Configuration page on the GUI. Expand Encoder > Slots > Slot 3 > CE-x
> Video > Video 1 > Video > Main Video > Video Encoder > Splicing folders in
the Advanced Video Processor Settings widget.
EN/LZT 790 0023/1 R16A
contain the same EventID.
Description
Virtual SCTE 104 channel used to route messages to
encoders. Different pins can share same channel. Different
encoders can share same channel.
When the parameter is set to Open a message is sent when
the pin goes from Closed state to open state. When the
parameter is set to closed a message is sent when the pin
goes from open state to closed state. Splice latched mode
defines the trigger for the Out of network message.
0 (default value) indicates immediate and a value less than 4
will be treated as immediate. A splice point is inserted at the
earliest possible opportunity. If a value is set for the pre-roll, a
splice point shall be inserted that many seconds after the GPI
pin contact change has been signalled.
0 (default value) indicates immediate and a value less than 4
will be treated as immediate.
If set to Automatic a Return to network splice shall
automatically be inserted after the time set for the Splice
Duration has elapsed from when the Out of Network splice
was signalled.
Added to both Out and Return pre-roll.
If set to Present, the value in the Provider Avail Id is inserted
into the output SCTE 35 message
Used as a reference to identify a specific Transport Stream
that the splice point is to be associated with.
Read only.
Web GUI Control