Ericsson AVP 1000 Reference Manual page 309

Table of Contents

Advertisement

Service Settings
The service parameters are available in the Properties widget on the Service
Configuration page if a service is selected in the Outputs widget. The same
settings are also available through the front panel under Output/<IP interface
name>/<Transport Stream name>/Service List/<service name>.
Table 5.117 Service Settings
Parameter
Values
Service ID
1 - 65535
PMT PID
16 to 8190
PCR PID
16 to 8190
BISS Key
None, (Hidden) selected Key
SDT Parameters
Provider
Name
Digital TV, Digital Radio, Teletext, Mosaic,
Service Type
Data Broadcast
(T/C) VCT Parameters (ATSC Only)
Short Name
String
Long Name
String
Major Channel
1 to 99
Number
Minor Channel
1 to 99
Number
Service Type
Digital TV; Digital TV (H.264); Digital Radio;
Data Broadcast
Source ID
0 to 65535
Hidden
Yes; No
Hide Guide
Yes; No
Error Monitoring (Not supported in this release)
Continuity Count Error
Threshold
Continuity Count Error
Sampling Window
Maximum Valid PID
Missing Period
EN/LZT 790 0023/1 R16A
Description
The PID assigned to the Program Map Table for the service.
The PID of the packetized elementary stream that transmits
the PCR for the current service.
The assigned security keys for the for Basic Interoperable
Scrambling System presets.
The name of the service provider.
The service name as it appears in the PMT.
The type of service as transmitted in the PMT.
Short description of the service
Long description of the service
PSIP major channel number
PSIP minor channel number
Type of service. Does not affect encoding.
Source ID
Sets Thresholds for error monitoring of service from IP input
only.
Not supported in this release
Web GUI Control
5-133

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avp 2000Avp 1000 1ruAvp 3000Avp 1000 seriesAvp 1000 1ru seriesAvp 2000 series ... Show all

Table of Contents