Web GUI Control
Parameter
Insertion Timeout
Broadcaster ID Mode
Default Servicename
Broadcaster ID Source
Broadcaster ID
Generic ANC
Generic ANC Extraction
Max ANC Bit Rate
Field 1
VBI Line 9 - VBI Line 22
VBI Line 6 - VBI Line 23
Field 2
VBI Line 272 - VBI Line
285
VBI Line 319 - VBI Line
336
ANC Component
This section describes the parameters associated with the component carrying
ancillary data.
The following parameters are available on the Component tab of the Properties
widget on the Service Configuration page when an ANC stream is selected in the
Outputs widget. The same parameters can be accessed through the
Output/<output name>/Transport Stream ID: <n>/Service List/<service
name>/Component List/<component name> menu on the front panel.
5-68
Values
Off, Auto, Default Only, Source Only
No, Input, Default
Off, On
100 to 2000 kbps
Off, Closed Caption
Off, VITC, WSS, WSS-AFD, Teletext System
B, Monochrome samples
Off, Closed Caption
Off, VITC, WSS, WSS-AFD, Teletext
System B, Monochrome samples
Description
Timeout in seconds for insertion of default source ID.
Gives what to insert as a broadcaster ID.
The default service name to be used.
Indicates if the Broadcaster ID is derived from the input,
the default or is invalid.
The Broadcaster ID that is currently being inserted into the
output stream.
Controls whether Generic ANC is extracted from the SDI
stream or not as per SMPTE 2038-2008.
The maximum data rate of the Generic ANC data output.
Specifies the content in the respective VBI lines. Set to Off
if the line in the incoming video does not carry any
information, Closed Caption for closed caption information.
Visible for 480i (525-line) input streams.
Specifies the content in the respective VBI lines. Set to Off
if the line in the incoming video does not carry any
information, VITC for Time Code, WSS for Wide Screen
Signaling, WSS-AFD for Active Format Detection and
Teletext System B for Teletext. Visible for 576i (625-line)
input streams.
Specifies the content in the respective VBI lines. Set to Off
if the line in the incoming video does not carry any
information, Closed Caption for closed caption information.
Visible for 480i (525-line) input streams.
Specifies the content in the respective VBI lines. Set to Off
if the line in the incoming video does not carry any
information, VITC for Time Code, WSS for Wide Screen
Signalling, WSS-AFD for Active Format Detection and
Teletext System B for Teletext.