Front Panel Control
IP Redundancy Mode
Index
Autorevert
Autorevert Delay
Active Interface
Line Speed
Duplex Mode
Default Virtual MAC Address
IP Address
Subnet Mask
Gateway Address
Physical Data Interface <m>
Use Data Interface Group 3_4
Model
Unit Name
4-24
Port Type
Direction
Index
Default MAC Address
Link Status
Link Up Time
TX Packets
RX Packets
IP Address
Active-Active, Active-Standby. Describes how the spare interfaces will
behave. For the Input data interface group only Active-Active is
supported and is a read only parameter. For the Output data
interface group both options are available.
Identifier of the interface group. Read only parameter.
Auto-revert to Primary, Auto-revert to Secondary. Shown only if the IP
Redundancy mode is set to Active-Standby. Determines what to do
when connection is lost.
The delay in seconds before automatic redundancy switching takes
place. Shown only if the IP Redundancy mode is set to Active-
Standby.
Read only parameter. Displays which interface is active. In Active -
Active redundancy mode both interfaces are active.
Auto, 100 Mpbs, 1 Gbps. The transmission speed of the link.
Auto, Full Duplex, Half Duplex. Determines whether data should be
transmitted and received in a time divided manner (Half Duplex) or
transmission and reception can happen at the same time over the
same link (Full Duplex). Auto is for automatic configuration.
Virtual MAC address assigned to the current Data Interface Group.
The IP address associated with the interface group.
The subnet mask associated with the interface group.
The gateway address associated with the interface group.
The physical data interface labelled as Ge <m> of the current data
interface group.
Ethernet. Read only parameter.
Output. Read only parameter.
Identifier of the physical data interface. Read only parameter.
The hardware address of the Ge <n> interface.
Link Down, Link Up. The status of the current physical data interface.
Read only parameter.
The time in days, hours, minutes and seconds the link is established.
Read only parameter.
Packets transmitted since the link is up. Read only parameter.
Packets received since the link is up. Read only parameter.
The IP address of the physical data interface.
If true data Ethernet ports Ge 3 and Ge 4 are used for control network
access to the unit.
If false the Ethernet control ports are used for control network access
to the unit.
Note: Changing this value will automatically reboot the unit.
The name of the current unit for displaying on the web user interface.